RO Control Panel

Our product range includes a wide range of infinity a5 ro control panel, infinity a9 hd 3-3 ro control panel, ro control panel, infinity a7 1-3 ro control panel, infinity a7 3-3 ro control panel and infinity a9 sd 3-3 ro control panel.

INFINITY A5 RO Control Panel

Request Callback

₹ 4500 / Piece Get Latest Price

Product Brochure
RO Plant Capacity1000 LPH
Power3 kW
Pump Configuration1Ø:1Ø
Automation LevelFully Automatic
PhaseSingle Phase
Control LogicMicroprocessor Based
Body MaterialMS Powder Coated
MaterialMild Steel
ColorBlue
Display TypeLCD Display
ProtectionsPhase Failure, Voltage Protection, Dry Run Protection, Overload Protection
Raw Water Pump HP2 HP
High Pressure Pump HP3 HP
BrandINFINITY
Automation GradeAutomation
Power SourceElectric
UseFor RO
Warranty1 Year
Products MaterialFRP
Motor Rating0.5 HP
INFINITY introduce A series microprocessor based preprogramed operational logics with all motor safety protection like over/under voltage-ampere, dry run, reverse phase, single phase, phase unbalancing with feed, product, chemical tank levels as well high/ low pressure safety inbuilt industrial RO control panels which is perfectly suitable for small as well as big size of RO systems. All kind of Auto MPV (Multi port Valve) can easy to connect with this control panels to make fully automatic industrial RO system.

INFINITY A9 HD 3-3 RO CONTROL PANEL

Request Callback

₹ 24200 / Piece Get Latest Price

Product Brochure
RO Plant Capacityupto 12.5 hp
Pump Configuration3Ø:3Ø
Automation LevelFully Automatic
Control LogicMicroprocessor Based
Body MaterialMS Powder Coated
Display TypeLCD Display
ProtectionsDry Run Protection, Phase Failure, Overload Protection, Voltage Protection
Raw Water Pump HP5 HP
High Pressure Pump HP7.5 HP
Brand nameINFINITY
Online TDS/COND, Ampere, Voltage, Plants Hours Auto flushing Pumps Dry run, Phase prevention, Level/pressure Protection All types of auto MPV supported
 A9 1-1 : 2 HP (l) RAW/ 3 HP (I) HPP
 A9 1-3 : 2 HP (l) RAW/ 5.5 HP (III) HPP
 A9 3-3 : 3 HP (III) RAW/ 7.5 HP (III) HPP
cutout : 283 x 283 mm 

Ro Control Panel

Request Callback

₹ 5000 / Piece Get Latest Price

Product Brochure
MaterialMild Steel
Power3 kW
PhaseThree Phase
CertificationsCE And RoHS Certified
Frequency50 Hz
Voltage410 V
BrandInficontrol
UsageUsed in Controlling The RO Systems
  1. Advanced Automation:

    • Our Water Treatment Control Panel is equipped with state-of-the-art automation features, enabling precise control and regulation of water treatment processes with minimal human intervention.Automated functions include chemical dosing, pH level monitoring, filtration control, and system diagnostics, ensuring consistent water quality and performance.
  2. Customizable Programming:

    • With customizable programming capabilities, our control panel allows users to tailor water treatment processes to specific requirements and applications.Programmable logic controllers (PLCs) and user-friendly software interfaces enable easy customization and adaptation to evolving operational needs.
  3. Remote Access and Control:

    • Our control panel supports remote access and control capabilities, allowing operators to monitor and manage water treatment systems from anywhere with internet connectivity.
    • Remote diagnostics, alarms, and alerts enhance operational efficiency and enable proactive maintenance to prevent downtime and optimize performance.
  4. Built-in Safety Features:

    • Safety is paramount in water treatment operations. Our control panel is equipped with built-in safety features such as emergency shutdown protocols, fault detection systems, and fail-safe mechanisms to ensure operational integrity and personnel safety.

INFINITY A7 1-3 RO CONTROL PANEL

Request Callback

₹ 12500 / Piece Get Latest Price

Product Brochure
RO Plant Capacity2000 LPH
Power3 kW
Pump Configuration1Ø:3Ø
Rated CurrentUpto 5000 Amps
Automation GradeAutomatic
PhaseThree Phase
MaterialAluminium
Current Rating240A
Type of Control PanelELECTRIAL CONTROL PANEL
BrandINFINITY
Display Type7 SEGMENT
Mount TypeWALLMOUNT
Bus BarCopper
ProtectionsVoltage Protection, Overload Protection, Dry Run Protection, Phase Failure
ShapeSQUARE
Usage/ApplicationWATER TREATMENT
Raw Water Pump HP2 HP
Dimension500 x 500
High Pressure Pump HP5 HP
Country of OriginMade in India
RINNING HOURSPLANT RUNNING HOURS
AUTO FLUSHINGIncrese membrane life

Minimum order quantity: 1 Piece

  • Supply voltage : 415VAC ± 10% 50Hz. , 3 Phase, 4 Wire.
  • Current range :0-30 A
  • Display Accuracy:Voltage : 0.25% ± 1 digits.
  • Current : 0.25% rdg ± 1 digits.
  • Voltage Resolution (Dispaly) : 1 V
  • Current Resolution (Display) : 0.1 A
  • Environmental:
    1. Working Temp : 0 to 55° C
    2. Storage Temp : -5 to 70° C
    3. Relative humidity : 0 – 95 % Non-Condensing
    4. Warm up time :10 Sec
  • Enclosure:
    1.Mounting : Panel mounting.
    2.Dimensions : 
    Cutout 215 (W) x 190 (H).
    All dimensions are in mm.


  • Suited for Small and Medium size RO plants.
  • Preprogrammed RO operation, process interlocks and time delays.
  • Interactive Auto RO operation through panel keys in case of faults.
  • Provides for operation with Automatic Multi-Port valves through handshaking inputs.
  • Plant RUN time display
  • Flow Rate / Cumulative Volume display (Optional).
  • Conductivity display with pre-alarm and trip settings.
  • Low Pressure, High Pressure switch inputs.
  • Raw Water and Product Water Tank level inputs.
  • Flush Solenoid and Dosing Pump power outputs.
  • Easy User Programmable Settings.
  • Password Protected Process and Electrical Parameter Settings.
  • 4 Key Interface and LCD for Control and Onsite Programming.
  • Process Status Message Display.
  • Front Panel LED indications for active devices.
  • Auto / Manual Operation.
  • Pump Motor Voltage / Current display and Pump Motor Protection.
  • Phase Reversal and Single phasing protection.
  • Pump Protection in Manual Mode as well.
  • Compact, Panel Mounting.

INFINITY A7 1-3 RO CONTROL PANEL

Request Callback

₹ 12500 / Piece Get Latest Price

Product Brochure
RO Plant Capacity2000 LPH
Pump Configuration1Ø:3Ø
Control LogicMicroprocessor Based
Body MaterialMS Powder Coated
Display TypeLED Indicators Only
ProtectionsVoltage Protection, Phase Failure, Dry Run Protection, Overload Protection
Raw Water Pump HP3 HP
High Pressure Pump HP5 HP
Brand NameINFINITY
Online TDS/COND, Ampere, Voltage, Plants Hours Auto flushing Pumps Dry run, Phase prevention, Level/pressure Protection All types of auto MPV supportedA7 1-3 : 2 HP (l) RAW/ 4.5 HP (III) HPP

INFINITY A7 3-3 RO CONTROL PANEL

Request Callback

₹ 14500 / Piece Get Latest Price

Product Brochure
Plant Capacity6–10 m³ hr
RO Plant Capacity5000 LPH
Control TypeRelay Based
Pump Configuration3Ø:3Ø
Panel Voltage415 V AC
ApplicationDrinking Water, Process Water, Industrial RO, Packaged Water
Enclosure MaterialMild Steel
Enclosure RatingIP55
Display TypeLED Indication
ProtectionHigh Pressure, Dry Run, Low Pressure, Tank Level
Online TDS/COND, Ampere, Voltage, Plants Hours Auto flushing Pumps Dry run, Phase prevention, Level/pressure Protection All types of auto MPV supportedA7 3-3 : 3 HP (l) RAW/ 7.5 HP (III) HPP

INFINITY A9 SD 3-3 RO CONTROL PANEL

Request Callback

₹ 38500 / Piece Get Latest Price

Product Brochure
RO Plant CapacityUpto 20 HP
Pump Configuration3Ø:3Ø
Automation LevelFully Automatic
Control LogicMicroprocessor Based
Body MaterialMS Powder Coated
Display TypeLCD Display
ProtectionsPhase Failure, Dry Run Protection, Overload Protection, Voltage Protection
RWP HP10 HP
HPP HP20 HP
Online TDS/COND, Ampere, Voltage, Plants Hours Auto flushing Pumps Dry run, Phase prevention, Level/pressure Protection All types of auto MPV supportedA9 SD : 10 HP (III) RAW/ 20 HP (III) HPP

INFINITY A1T RO CONTROL PANEL

Request Callback

₹ 3850 / Piece Get Latest Price

Product Brochure
RO Plant Capacity250 LPH
Pump Configuration1Ø:1Ø
Automation LevelSemi-Automatic
Body MaterialMS Powder Coated
Display TypeLED Indicators Only
ProtectionsOverload Protection, Voltage Protection
Raw Water Pump HP1 HP
High Pressure Pump HP3 HP
Brand NameINFINITY
Display Online TDS Auto flushing facility Level/pressure Protection 0.75 HP (l) RAW/ 1.5 HP (I) HPP 141 x 171 mm

Infinity A9 Ro Control Panel

Request Callback

₹ 12500 / Piece Get Latest Price

Product Brochure
Power1 kW
MaterialMild Steel
PhaseThree Phase
Country of OriginMade in India

Minimum order quantity: 1 Piece

Micro-Controller based RO CONTROL Panel 

.         Easily Configure Auto Multi Port Valves (AMPV)

·         Displays Total Running Hours.

·         LCD Display (16 Bit 2 line).

·         TDS Display

·         Automatic AMPEARE Settings (RWP & HPP).

·         Dual Mode operations : AUTO &  MANUAL

·         HIGH Voltage & LOW Voltage Protections

·         Overload and Dry Run Protections for RWP & HPP.

·         LPS & HPS Provisions.

·         Auto FLUSH,UV & Dosing Pump Connections provision

·         Floats Provisions for  Raw Water Tank & Treated Water Tank.

·         Flush Periods & Flushing Times.

·         All settings are editable according to our requirements.

Technical Specification:

·         Input Voltage: 230 V AC

·         Operating 12 VDC

·         Current Max : 30A

·         Working Temperature: 0-50o C

 

·         Overall Size : 283 X 283 MM

  • Preprogrammed RO operation, process interlocks and time delays.
  • Interactive Auto RO operation through panel keys in case of faults.
  • Provides for operation with Automatic Multi-Port valves through handshaking inputs.
  • Plant RUN time display
  • Flow Rate / Cumulative Volume display (Optional).
  • Conductivity display with pre-alarm and trip settings.
  • Low Pressure, High Pressure switch inputs.
  • Raw Water and Product Water Tank level inputs.
  • Flush Solenoid and Dosing Pump power outputs.
  • Easy User Programmable Settings.
  • Password Protected Process and Electrical Parameter Settings.
  • 4 Key Interface and LCD for Control and Onsite Programming.
  • Process Status Message Display.
  • Alarm/Fault Message Display.
  • Front Panel LED indications for active devices.
  • Auto / Manual Operation.
  • Pump Motor Voltage / Current display and Pump Motor Protection.
  • Phase Reversal and Single phasing protection.
  • Pump Protection in Manual Mode as well.
  • Compact, Panel Mounting.
  • There are seven LEDs at front panel, for motor status, fault status & Fault Alarm status.

INFINITY A1 Without TDS RO CONTROL PANEL

Request Callback

₹ 3650 / Piece Get Latest Price

Product Brochure
PhaseSingle phase
Rated Voltage220/240 V
MaterialMild Steel
Power230v AC
Usage/ApplicationControl RO System
Country of OriginMade in India
BrandINFINITY
CUT-OUT SIZE141 x 171 mm
Display Online TDS Auto flushing facility Level/pressure Protection 0.75 HP (l) RAW/ 1.5 HP (I) HPP 141 x 171 mm
X

Contact Us

Deep Gandhi (Director)
Infinity Aqualogy
Pune-Nashik Highway, Gat No. 150/2, Chimbali Phata, B/H Shantai Patsanstha, Village Kuruli, Ta-Khed
Pune - 410501, Maharashtra, India

Get Directions
Send Email
Share: